SHROUD - Part #: 801527
COND SHROUD, TBB-24-48 .070 BLACK CHIPBOARD COVERS COIL
Please login to purchase. If you don't have an account, please register today!
True Parts OEM - TBB-24-48G-S: Find authentic replacement parts and accessories for your True OEM cooler, designed to ensure optimal performance, durability, and reliability.
COND SHROUD, TBB-24-48 .070 BLACK CHIPBOARD COVERS COIL
SPACER KIT, DOOR HANDLE, 3/4" SILVER, SET OF 2)908621 SET OF 2)908621 SPACERS
START COMPNT KIT AE4440Y-AA1A INCLUDES: 1) 992815 OVERLOAD, 1) 992820 RELAY, 1) 992816 START CAPACITOR
START COMPNT KIT NEK6187Z 268AA92D9AY INCLUDES: 1) 946263 RELAY, 1) 991624 OVERLOAD, 1) 947239 START CAPACITOR
RELAY, 9660C-+-182, 3ARR12PM22 3ARR12PC22, 82632, 8200EMBH20 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START KIT (213121) W/ COMPRESSOR (916109) TPA9417YXA (TP127AR)..USED WITH AEA4440AXA (AE234AS), AEA4440YXA (AE630AT), & TPA9417YXA (TP127AR) COMPRESSORS
OVERLOAD, 8300MRTA78 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.FOR COMPRESSORS AEA4440YXA (AE630AR) AEA4440AXA (AE234AS)
CAPACITOR, START 85PS110C90 ALTERNATE 85PS110C14 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.COMPRESSOR 800133 AEA4440AXA (AE234AS) & AEA4440YXA (AE630AR)
RELAY, 8200EMBE43 (501-94155 EMB) THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START COMPNT KIT 971036 FOR COMPRESSOR 842127 AEB4448YXC (SEA660KT)..LG 6/2017...USE START COMPNT KIT 885503 FOR COMPRESSOR 842103 AEA4440YXD (AE630ER)..USE START COMPNT KIT 971036 FOR COMPRESSOR 842127 AEB4448YXC (SEA660KT)..LG 6/2017...AEB4448YXC (AE660JT), AEA4440AXD AE234EL; AEA2415AXC AE334JT; AEA440YXD;AE630ER/ET,
CAPACITOR, START 85PS250D06 ALTERNATE 85PS250A52 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START COMPNT KIT (911292) FOR COMPRESSOR (842081) AEA4440YXC (AE630JR).LG 6/2017...FOR COMPRESSOR (842051) AEA4430YXD (AE540ET) USE START COMPNT KIT (954163)..LG 6/2017...LG 6/2017...FOR COMPRESSOR (842080)1/3HP AEA4440AXC (AE234JL) USE START COMPNT KIT (911607)..LG 6/2017...
OVERLOAD, 8300MRPM76 ALTERNATE MRP38AMZ-34 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.START COMPNT KIT (911292) FOR COMPRESSOR (842081) AEA4440YXC (AE630JR).LG 6/2017...FOR COMPRESSOR 842127 AEB4448YXC (AEA660KT) USE START COMPNT KIT (971036) ..LG 6/2017...
RELAY, 8200EMBJ79, 3ARR12-PC13 ALTERNATE 501-94135 EMB THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE COMPONENT KIT (911292) FOR COMPRESSOR (842081) AEA4440YXC (AE630JR).
ST CAPACITOR CAP 90528-2 FOR 1/3 HP AE630JR 220V LARGE CAPACITOR CAP (USED W/ VARIOUS COMPRESSORS EX. AE630JR)
ST CAPACITOR CAP 90528-1 FOR 1/3 HP AE630AR 115V SMALL CAPACITOR CAP (USED W/ VARIOUS COMPRESSORS EX. AE630AR)
START COMPNT KIT AEA4440YXA 802116/802118/802117 FOR COMPRESSOR AK163ET-032-B4 800135 INCLUDES: 802118 START CAPACITOR, 802117 OVERLOAD, 802116 RELAY
START COMPNT KIT AE630ER 802217/802157/802138 FOR COMPRESSOR AEA4440YXD (AE630ER). INCLUDES 802138 RELAY, 802217 OVERLOAD, 802157 START CAPACITOR
BRACKET, ST CAPACITOR 57068-7 FOR 1/3 HP A3630AR 115V (SHORTER BRACKET)
BRACKET, ST CAPACITOR 57068-5 FOR COMP (AE530AR) HOLDS START CAPACITOR FOR MODELS AEA2380ZXA AE560AT-916-A4AEA2411ZXA AE820AT-906-B4AEA2411ZXC AE820JT-906-B4AEA3417YXA AE520AR-719-A2AEA3417YXC AE520JT-727-B4AEA3425YXA AE530AR-718-A2AEA4430YXC AE540JR-277-A6AEA4430YXD AE540ET-203-B4AEA4440AXA AE234AL-725-B4AEA4440YXA AE630AR-717-A2AEA4440YXC AE630JR-717-A2AEA4440YXD AE630ER-717-A2AEA4448YXA AE660AT-724-B4AJA2425ZXA AJ532AT-430-B4AJA2425ZXC AJ532JT-430-B4AJA7461YXA AJ250AT-435-C4AKA4460YXA AK168AT-047-A4AKA4460YXA AK168AT-0
SURGE PROTECTOR VDS16P (115) GDM-33 & UP NOT AVAILABLE FOR R-290/HC UNITSHARDWIRE. PROTECTS COMPRESSOR ONLY. Shut off power to compressor for 180 seconds if voltage goes below 105 or above 126V. Every 180 seconds checks power and comes on when within correct range. All other lighting/motors remain on if there is sufficient power. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE'S WARRANTY.
SURGE PROTECTOR VDS16P (230V) GDM-33 & UP 208/230/220 HARDWIRED. PROTECTS COMPRESSOR ONLY. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE'S WARRANTY. NOT AVAILABLE FOR R-290/HC UNITS
SURGE PROTECTOR PME-110-TR 115V 1/3HP & LOWER NOT AVAILABLE FOR R-290/HC UNITSPLUG IN STYLE.. PROTECTS COMPRESSOR ONLY. Shut off power to compressor for 180 seconds if voltage goes below 105 or above 126V. Every 180 seconds checks power and comes on when within correct range. All other lighting/motors remain on if there is sufficient power. FOR 1/3HP OR LESS MODELS. PLUG COMPRESSOR POWER CORD ONLY INTO SURGE PROTECTOR. DO NO PLUG MAIN POWER CORD INTO PROTECTOR!
SURGE PROTECTOR 115V PFN110-MD MAXIMUM OF 1 HP HARDWIRE , MAXIMUM OF 1 HP. PROTECTS COMPRESSOR ONLY. Shut off power to compressor for 180 seconds if voltage goes below 105 or above 126V. Every 180 seconds checks power and comes on when within correct range. All other lighting/motors remain on if there is sufficient power. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE''''''''S WARRANTY. NOT AVAILABLE FOR R-290/HC UNITS
SWITCH, ROCKER 74-409933-008 00/S/B 049933018 0W/18GA OVER