START/RUN COMPONENT - Part #: 802223
OVERLOAD, 8300CRTK87 1/2HP ALTERNATE CRT16AGN-130 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.START COMPNT KIT 880329 W/COMPRESSOR 842405 AK168AH/AK168AT (AKA4460YXA)..
Please login to purchase. If you don't have an account, please register today!
True Parts OEM - TWT-72: Find authentic replacement parts and accessories for your True OEM cooler, designed to ensure optimal performance, durability, and reliability.
OVERLOAD, 8300CRTK87 1/2HP ALTERNATE CRT16AGN-130 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.START COMPNT KIT 880329 W/COMPRESSOR 842405 AK168AH/AK168AT (AKA4460YXA)..
RELAY, P82934 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USED WITH AK163ET (AKA9441AXD) COMPRESSOR
RELAY, 8200EMBJ90 ALTERNATE 3ARR2-KCR119S GE THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START COMPONET KIT (213475) USED WITH #842409 COMPRESSOR AKA4460YXD (AK168ET-407A4)USE START COMPONET KIT (213471) USED WITH 842410 COMPRESSOR AK169EH/AK169ET (AKA4476YXD)..USED W/ AK163JT (AKA9441AXC) COMPRESSOR(OBS)
RELAY, 8200EMBJ89 ALTERNATE 3ARR2-KCR178S THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT. START COMPNT KIT 909009 USED W/ 842408 AK169JH/AK169JT (AKA4476YXC) COMPRESSOR..
RELAY, EMB 501-94191H 8200EMBJ75 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START KIT (213126) FOR COMPRESSOR (963040) TPA9421YXA TP119AR-021-E4KX. USED W/ COMPRESSOR TP119AR-021-A2
OVERLOAD, TI MRA5782-34 8300MRAR85 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.FOR COMPRESSOR 925050 TP119AR-021-A2
START COMPNT KIT AKA4460YXA USED W/ AK168AH/AK168AT (AKA4460YXA) COMPRESSOR 842405. INCLUDES: 802115 START CAPACITOR, 802223 OVERLOAD, 802113 RELAY
START COMPNT KIT TP119AR-021-A 802115/802289/802288/802270 INCLUDES: 1)802115 START CAPACITOR; 1)802289 OVERLOAD((NOTE WILL CHANGE TO 962979 WHEN 802289 DEPLEATED); 1)802288 RELAY, 802270 CAP w/COMPRESSOR 842159
START COMPNT KIT AKA4476XYC 802230/802156/802160 USED W/ 842408 AK169JH/AK169JT (AKA4476YXC) COMPRESSOR. INCLUDES: 802230 RELAY, 802156 OVERLOAD, 802160 START CAPACITOR
OVERLOAD, 8300MRAR16 MRA5775-34 THIS CAN BE PURCHASED INDIVIDUALLY OR AS A KIT.USE START KIT (213126) FOR COMPRESSOR (963040) TPA9421YXA TP119AR-021-E4KX. REPLACES THE 802289 OVERLOAD PREVIOUSLY USED.
SURGE PROTECTOR VDS16P (115) GDM-33 & UP NOT AVAILABLE FOR R-290/HC UNITSHARDWIRE. PROTECTS COMPRESSOR ONLY. Shut off power to compressor for 180 seconds if voltage goes below 105 or above 126V. Every 180 seconds checks power and comes on when within correct range. All other lighting/motors remain on if there is sufficient power. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE'S WARRANTY.
SURGE PROTECTOR VDS16P (230V) GDM-33 & UP 208/230/220 HARDWIRED. PROTECTS COMPRESSOR ONLY. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE'S WARRANTY. NOT AVAILABLE FOR R-290/HC UNITS
SURGE PROTECTOR 115V PFN110-MD MAXIMUM OF 1 HP HARDWIRE , MAXIMUM OF 1 HP. PROTECTS COMPRESSOR ONLY. Shut off power to compressor for 180 seconds if voltage goes below 105 or above 126V. Every 180 seconds checks power and comes on when within correct range. All other lighting/motors remain on if there is sufficient power. FIELD INSTALL WOULD VOID UL APPROVAL AND TRUE''''''''S WARRANTY. NOT AVAILABLE FOR R-290/HC UNITS
THERMOMETER HB-120L-VERTICAL WITH LOGO & SCREW HOLE
THERMOMETER XT11S-4117-BLU INCLUDES 4 FT SENSOR; BUILT IN 115V TRANSFORMER; . HAS 1 MINUTE DELAY. PROBE INCLUDED. **IF USED BEFORE 5/20/19 WILL ALSO NEED 808466 CONTROL BUMPER KIT** PCN 10707PROBE IS NOT AVAILABLE SEPARATELY
SCREWDRIVER, T-7 TORX 36512 T7 X 50MM USED TO CALIBRATED DANFOSS CONTROL
TRANSFORMER 015-0058-01 220V FOR CONTROLS: 831904; 831958; 831984; 831978
TRANSFORMER BE110805GAA REPLACES 015-0054-01 FOR DIGITAL FAHRENHEIT AND DIXELL #XR160C-0P0F1 CONTROL REPLACES 831909
PROBE, COPPER 3/16 X 11" ATTACHES TO COIL FOR CONTROL TO FEED THROUGH. ONE END BRAZED CLOSED
VOLTAGE REGULATOR ASP15-11 PROTECTS THE COMPRESSOR AND ALL ELECTRICAL PARTS** NOT AVAILABLE FOR R-290/HC UNITS**
VOLTAGE REGULATOR ASP10-22 HARDWIRED. PROTECTS COMPRESSOR AND ALL ELECTRICAL PARTS. FOR UP TO 10 AMPS. FIELD INSTALLATION VOIDS UL APPROVAL AND TRUE'S WARRANTY. ** NOT AVAILABLE FOR R-290/HC UNITS**